SrNo-232418/19 ; 35 Station Contactor Mechanical Endurance/ Life Test Bench

It is capable of testing 35 nos of Latching and Non-Latching Contactors simultaneously in a closed loop system (2 Digital Inputs per Contactor for continuity).
24×7 operation with automatic Pause/ Resume feature in case of failure of Raw power.
2 nos of in-built Manual Voltage sources: 0-600V AC/DC (full wave rectified waveform).
4 Nos of External voltage sources can be connected.
35 Nos of Contactors are divided in 7 groups, each of 5 Contactors.
Each group can have Coil Voltage options of 2 internal and 4 external voltage sources.
Data Logging and Traceability
Test Recipe Master: Add/ Edit/ Delete Test Recipes
Result CSV file direct email facility. No need of Pen drive.
Auto Mode: For Production Use
Calibration Mode: For Calibration of internal instruments
Multi-User system with different authorities: Engineering, Quality, Maintenance, Production, Operator.
System Health Check: For Preventive and Corrective Maintenance
Industry 4.0 compliant system
Machine to Machine communication capability
21CFR compliant